This extraordinary facility was recognized with a Lighting Control Innovation Award of Merit in the 2026 Illumination Awards held by the Illuminating Engineering Society. Design by AES Lighting by AES Engineering. Photography by Latreille Architectural Photography.
The Lighting Control Innovation Award was created in 2011 as part of the Illuminating Engineering Society’s Illumination Awards program, which recognizes professionalism, ingenuity, and originality in lighting design. The Lighting Controls Academy is proud to be a founding and longstanding founding sponsor of the Lighting Control Innovation Award, which recognizes projects that exemplify the effective use of lighting controls.
As Western Canada’s only degree-granting integrated facility for early childhood care, research, and education, this new childcare education center not only increased the post-secondary program’s student capacity by 25%, it also added 74 new childcare spaces. Accordingly, the facility’s design had to serve the needs of different age-based cohorts of children, parents, and both university faculty and students.
Nestled within a forested campus, the center prominently features mass timber architecture. The interior lighting challenge was to complement this design while also providing effective and appropriate lighting for such disparate spaces as nap rooms, staff offices, and the central Strada.
In keeping with the architecture’s biophilic approach and to contribute to achieving LEED Gold and Step Code 4 energy performance, the lighting and lighting controls were designed to maximize daylight harvesting.
With photosensors moderating lighting output, linear luminaires are split into primary and secondary daylight zones. This lighting controls approach extends to multiple spaces within the center: the ECCE Lab, Level 1 open areas, kitchens, enclosed offices and the student study room. Customizable user experience was also addressed with each stairwell luminaire capable of individual dimming.
The specific needs of a childcare facility were also carefully considered. Nowhere more so than the nap room. With programmed wake, quiet time, and nap scenes, the controls aid and accommodate the function of the space. For naptime, the lighting dims from 100% to 1% within 10 seconds with the occupancy sensors then automatically disabled for one hour. There is even a projector, within the Level 1 area, equipped with a theatre setting for movies.
Now open, the new center achieved Step Code 4 energy performance with 40% lower energy use than comparable buildings. By adding childcare spaces and expanding the ECCE program, the center will add value to the community for years to come.

On/Off/Dim keypads control the spherical pendants hung at various heights that encourage movement through the Strada towards the administration and open play areas.

Separately controlled gimbaled downlights illuminate the entry signage of the Open play area. On/Off/Dim keypads control the linear luminaires in the Cubby room.

Linear luminaires split into primary and secondary daylighting zones use photosensors to automatically adjust the light output based on incoming daylight autonomy.

Five rows of non-daylighting general lighting zones adjacent to secondary daylight zones operate independently in the Open play area with On/Off/Dim keypad control.

Linear luminaires in the white painted washroom balance intensities against wood finishes and luminaires of equal type in the Cubby, Open play and Kitchen areas.

The Nap room lighting control scene enables the linear and wall luminaires to smoothly dim to 1% while disabling the occupancy sensors for one hour.

Suspended cylinders split into two primary and one secondary daylighting zones use photosensors to automatically adjust the light output based on incoming daylight autonomy.

On/Off/Dim keypads independently control pendants and wall mounted luminaires. Suspended cylinders are controlled in a primary daylighting zone below the long clerestory window.

Each wall mounted luminaire in the stairwell can be individually dimmed so that the maximum brightness for each luminaire appears uniform when raised and lowered.

Rear exterior view of the Education Centre at twilight showcasing the lighting intensities volumetrically filling the interior space showcasing the wood glulam ceiling and structure.